Your solar app shows exports at lunchtime, but you’re still buying electricity when the air con, oven and dishwasher are running after work. With the Solar Sharer Offer, eligible households can shift some grid use to midday instead of paying for it later. But what size solar battery do you need to make that work?
Table of Contents
ToggleStart with the electricity you use after solar production drops, not the offer’s free-usage limit. This guide shows how to compare rooftop-only charging with a scheduled grid top-up, and how to tell when a bigger battery won’t help.
Key Takeaways
- Size your usable battery capacity around the evening and overnight grid electricity you can regularly replace, after allowing for a backup reserve and discharge losses.
- The regulated offer’s 24 kWh threshold applies to eligible grid usage during the daily window in South East Queensland. It’s not a battery size recommendation or a separate allowance for each appliance.
- Model solar-only charging first, then add a grid top-up limited by your equipment, spare battery capacity and other grid imports. Compare the whole bill before switching plans.
What size solar battery do you need for the Solar Sharer Offer?
For the Solar Sharer Offer, choose a battery that can cover the evening and overnight grid use you regularly want to replace. Then check how much rooftop solar can refill it and how much your system can import in the three-hour window after allowing for other household loads.
A battery’s nameplate capacity is its total storage, while usable capacity is the portion the manufacturer makes available. If you set aside a backup reserve for outages, the space you can cycle for bill savings is smaller again. Ask for the daily working capacity in the quote, not just the number on the box.
Kilowatt-hours (kWh) measure energy stored or used. Kilowatts (kW) measure how fast energy moves. That distinction matters both at lunch, when the battery has a deadline to charge, and at dinner, when the oven and air con may draw more power at once than the battery can supply.
Our general guide to choosing the right solar battery size covers the basics; the steps below test whether the midday tariff changes the size you’d pick.
Who can get the Solar Sharer Offer on the Energex network?
The regulated Solar Sharer Offer is an opt-in residential standing offer that started on 1 July 2026. In South East Queensland, check that your address is on the Energex network, your household has a smart meter, your retailer offers the plan and you don’t receive power through an embedded network. You don’t need solar panels or a battery to sign up, and the retailer won’t put you on it automatically.
As of November 2026, the regulated usage rate is 0 cents per kWh for eligible grid electricity up to the 24 kWh threshold in the 11 am to 2 pm AEST window each day in South East Queensland. The rate covers eligible usage only, so daily supply charges, separately billed controlled-load usage and time-of-use charges outside the window still apply. Your retailer may charge for excess usage at a rate subject to the regulated cap.
The Australian Energy Regulator’s Energy Made Easy guide explains eligibility and charges. Check the retailer’s Basic Plan Information Document (BPID) for your address and how the retailer applies the threshold on your bill. Don’t assume an advertised market plan with free hours has the same terms as the regulated standing offer.
Small-commercial accounts don’t qualify for the regulated residential offer, even if the property is on Energex and has a smart meter. If you run a shop or office, use the same sizing method with your actual business tariff and trading hours. A business that uses much of its power while the panels are generating may benefit more from using that solar directly than from storing it for later.
How to work out your evening and overnight electricity use
Start with interval data, which shows how much electricity your smart meter records in each time slot. A quarterly total can’t tell you if your biggest loads run at lunchtime or after sunset. Draw a line where your solar output stops covering the load, then total the billed general-use grid imports through to the next morning, keeping any separate controlled-load circuit out of the calculation unless your installer confirms the battery can serve it.
- Pick days that reflect real life. Use weekdays and weekends, with both warm and cool weather if you have the data. Use your usual evening load as a starting point, then test larger loads such as a hot spell when the air con runs late.
- Separate loads you can move from loads you can’t. If the car sits in the driveway during the day, test charging it directly before you size the home battery to feed it overnight. Keep cooking, lighting and any cooling you need after dark in the evening model.
- Check what your meter doesn’t show. Solar can hide part of the household’s load, and an existing battery can hide some purchases it already offsets. If you’re upgrading, use inverter or energy-monitor data with meter readings to estimate the load you’d ask the replacement system to serve.
- Mark the hours you care most about. If your main goal is to reduce peak imports, test the evening peak on its own. Covering the whole night may need more capacity while avoiding fewer costly imports per extra kWh.
Look at discharge power as well as total energy. A battery can still have charge left when several appliances pull more kW than the inverter can deliver. Your meter will show imports during those spikes even if the battery is large enough, on paper, to cover the night’s kWh total.
How much surplus solar can refill a battery without grid charging?
Use your inverter’s production and home consumption data, or use smart-meter exports as a starting point if you don’t already have a battery. Solar surplus is what’s left after the property uses what it needs at that moment. If a battery already takes some of that surplus, exports alone will understate how much was available.
If you move a pool pump or EV charge into the day, subtract the solar those loads now use before you assign the rest to storage.
Check how much surplus the proposed system can actually accept in each interval. An export spike won’t fill a battery if the charging hardware can’t keep up, and some energy goes into conversion losses. The grid window closes at 2 pm, but spare rooftop solar can still refill the battery after that.
Worth checking: If your panels already fill the battery on sunny days, a lunchtime grid top-up may have more value on overcast days than on clear ones. Save both scenarios so you don’t buy extra capacity based on the best day of the year.
Adding or upgrading storage? Compare options with SolarThoughts® through its solar battery installation service, using your actual interval data and existing equipment details.

How much can a grid top-up add in three hours?
Start with the sustained AC grid-charge rate your inverter and battery can achieve on your connection. The inverter’s headline output rating doesn’t tell you how fast it can charge from the grid. Some systems can’t schedule grid charging, some slow down as the battery fills, and a site import limit can cut the available charging power when an EV charger or other big load runs at the same time.
For a rough check, take the smallest of three limits: grid-charge kW multiplied by available hours, spare storage divided by charge efficiency, or remaining free grid usage after other eligible imports. That gives a ceiling on grid input, not stored energy. Multiply by charge efficiency to estimate what reaches the battery.
Leave room for solar that will arrive later if you want to store it, and check the actual charge schedule in shorter intervals so you don’t count the same inverter capacity twice.
In this illustrative example, a home wants to replace 8 kWh of evening and overnight grid use. Its system can sustain 3 kW from the grid, so it can take in at most 9 kWh across the three hours before losses. The example uses 90% charge efficiency on grid input and 90% discharge efficiency from storage to the home.
On the cloudy day below, other eligible grid imports, such as EV charging and household loads after available solar, total 18 kWh in the window. Using the daily threshold for this example, that leaves 6 kWh of grid input, or 5.4 kWh stored, for the battery. Assume the equipment can accept that top-up alongside the solar shown and that the charging schedule leaves room for later solar.
| Daily working storage after reserve | Clear day: solar only, up to 10 kWh stored | Cloudy day: solar only, up to 4 kWh stored | Same cloudy day: solar plus grid top-up, up to 9.4 kWh stored |
| 6 kWh | Up to 5.4 kWh delivered | Up to 3.6 kWh delivered | Up to 5.4 kWh delivered |
| 10 kWh | Up to 9 kWh delivered | Up to 3.6 kWh delivered | Up to 8.5 kWh delivered |
| 14 kWh | Up to 9 kWh delivered | Up to 3.6 kWh delivered | Up to 8.5 kWh delivered |
The table starts each day with an empty working range above the backup reserve. It shows what the battery could deliver after losses, not what the home necessarily consumes. In this example, the 10 kWh option can meet the 8 kWh target on the clear day and on the cloudy day with a top-up, subject to discharge power.
The 14 kWh option delivers nothing extra on those days because it doesn’t have any more energy to draw on. On another day you may begin with charge left over, have less solar, or have fewer usable minutes for a top-up. Use your own data rather than treating any of these sizes as a recommendation.
When an EV, backup reserve or older inverter changes the answer
An EV at home at lunchtime can use the window directly instead of taking a detour through the home battery. But the car, battery and other appliances share the same eligible grid usage threshold and the same connection. Test a staggered schedule or compatible load management if running everything together would crowd out the top-up.
If your car is away during the day, use its real charging pattern in the model rather than assuming the home battery must cover every trip.
Backup for outages calls for a separate calculation. List the circuits you need in a blackout, check their power draw and how long you need them, then confirm the system can supply those circuits. A high backup reserve can make sense for a fridge and other essentials, but holding that energy back means it won’t offset ordinary evening imports.
An older inverter or an underperforming array can give you a misleading result. When we look at an upgrade or retrofit, we’d check for faults, changes in shading and settings that limit charging before recommending more storage. The grid-charge modes and power limits of the proposed setup can change the result more than another battery module.
How to compare your whole electricity bill before switching
Run the same set of days against your current plan and the Solar Sharer plan. Try the Solar Sharer plan with direct load shifting only, then with solar-only storage and with an optional grid top-up. Compare a full year of interval data when available, so a run of clear days doesn’t stand in for winter, holidays or changes in how often the EV is home at lunch.
Include daily supply, usage outside the window, excess window usage, controlled load and feed-in credits. If you divert rooftop exports into storage, include the credit you give up. If you already have a competitive feed-in rate or a plan that suits your evening usage, the midday rate alone can’t tell you whether switching helps.
Once a schedule is running, use the meter and your bill to check what actually happened, not just the battery app’s estimate.
Compare installed quotes only after you’ve identified the storage you can regularly fill and use.
The Clean Energy Regulator’s Cheaper Home Batteries Program guidance explains a separate scheme that can support eligible homes and businesses. For that scheme, confirm eligibility and use a Solar Accreditation Australia (SAA) accredited installer with battery endorsement. A federal battery discount doesn’t qualify you for the residential electricity offer or make unused capacity worth buying.
Common Mistakes to Avoid
- Using the 24 kWh threshold as a shopping list. It’s a tariff threshold for eligible usage, not an engineering target. Size to the energy you can store and put to work after sunset.
- Using the rated inverter output as the grid-charge rate. Charge and discharge power can differ. Get the sustained grid input your configuration supports, including any site or scheduling limits.
- Counting gross solar production as spare energy. Your property uses some production as it happens. Model the surplus after daytime loads and revisit it if you schedule an EV or other equipment at lunch.
- Putting controlled-load hot water in the free column. The free-usage window doesn’t cover separately billed controlled load. Leave it in its own line on the bill comparison.
- Treating a high-load night as the norm. A bigger battery may help during a few unusually hot nights but sit partly idle most weeks. Repeat the comparison on ordinary nights and see how often the extra capacity comes into play.
Frequently Asked Questions
Do I need a 24 kWh battery for the Solar Sharer Offer?
No. The 24 kWh threshold applies to eligible grid use in the window, not battery storage. Size to evening demand and what you can refill.
Can a solar battery charge from the grid during the free hours?
Yes, if the system supports scheduled grid charging. Its charge rate, spare capacity and other eligible imports limit how much you can top up without a usage charge.
Do I need solar panels to get the Solar Sharer Offer?
No. Eligible residential customers can opt in with a smart meter even if they don’t have rooftop solar or a battery.
Can I charge my EV and home battery at the same time?
Yes, if your connection and equipment can handle both. Their grid imports share the same eligible usage threshold, so staggering may work better.
Is the Solar Sharer Offer available on cloudy days?
Yes. The regulated window runs daily regardless of weather. Cloud may reduce your own solar output and make a grid top-up more useful.
Can a 10 kWh battery cover a Queensland home overnight?
It depends on overnight load, backup reserve, losses and discharge power. Check the usable energy the battery can deliver against your meter data.
How much battery capacity do I need for blackout backup?
Add up the energy your essential circuits need for the outage you want to cover. Check their peak power draw and whether your system can run them.
Can a small business get the regulated Solar Sharer Offer?
No. Small-commercial electricity accounts don’t qualify. Use your business tariff and interval data when comparing battery sizes.
Does separately metered hot water qualify for the free window?
No. If the retailer bills your hot water on a separate controlled-load tariff, the controlled-load charge still applies.
Does every retailer apply the Solar Sharer usage threshold the same way?
Don’t assume so. Check the plan information and retailer billing terms for your address before basing a charge schedule on the threshold.
Conclusion
So, what size solar battery do you need? Look for the smallest option that regularly covers the evening grid use you want to replace and that your rooftop solar or a realistic grid top-up can refill. Keep backup needs separate, check the inverter’s charge and discharge limits, and judge the offer by the whole bill, not by the midday window alone.
Want to check your numbers? Contact SolarThoughts® with your interval data and current plan details to discuss a battery size and charging setup that fit your property.